Local Stock (US & UK) • Free Shipping& Tax Included

Subscribe to get 5% off for First Purchase

Fumeclear FC-350 User Manual

Written by David 

Published on May 9, 2026

  • Product Overview

  • Unpacking Inspection

  • Check Before Using

  • Symbols & Safety Precautions

  • Unit Components

  • Specifications

  • Installation & Use instructions

  • Troubleshooting

  • Filter Use & Maintenance

  • Important Use Considerations

This product conforms to applicable CE requirements and RoHS.

 

This product is suitable for applications where fumes are produced such as smoke, peculiar smells, dust, poisonous and harmful gas, soldering, laser marking & carving, printing, and medical care, etc. 

 

With the triple-filter design and powerful suction, the absorbing efficiency and filtration ratio can reach 99.97%. The purified air can be discharged directly indoors. 

Please check carefully to ensure that the following listed parts are included. If there are any missing or damaged items, please contact the customer service department. 

Name of Parts Qty Specification Remarks
Motor 1 Installed
Power Line 1 1.5M
Duct 1 75mm × 1.4m
Warranty Card 1
User Manual 1
Cotton Filter 5 1 of 5 is installed
HEPA Filter 1 Installed
Main Carbon Filter 2 Installed
Remote Control 1 Only for Digital Display Machine

Before switching on the power for the first time, please ensure that the following conditions exist, so as to guarantee safe operation. 

  1. The machine should be intact;
  2. The power switch should be in the OFF position; 
  3. The filter element(s) should be evenly placed; 
  4. The cover and box body should be installed securely; 

The speed-regulating button is adjusted to “OFF” Status;    

This manual utilizes certain symbols throughout which represent the following:

  • ATTENTION - CAUTION (Before use, please read and follow the safety precautions 

    below to prevent fire and personal injury.

  • FIRE HAZARD (This product is prohibited to be used in a high temperature 

    environment (above 80℃) or in a flammable, explosive or greasy environment. )

  • ELECTRICAL HAZARD (Supply wire must be grounded during operation.

    Internal electric voltage of the product is as high as 310V.)

  • INJURY HAZARD (Do not remove or install filter elements while the machine is 

    operating. Hands or other objects should not touch the rotating impeller.

    Dis-assembly of the product for inspection or maintenance must 

    be performed by professionals.)

Model FC-350
Air Inlet Interface φ75mm
Input Voltage □ AC110V / □ AC220V
Maximum Power 350W
Filtering Efficiency 0.3μm 99.97%
Noise <68dB
Typical Flow Rate 460m³/h
Dimension 400 × 300 × 560mm
Weight 28KGS

8.1  Filtering Core Installation

Open the top cover and correctly install the high-efficient filtering core, medium-efficient filtering core, primary-efficient cotton filtering with top cover and press for buckle hasps at the two sides.

 

8.2  Suction Duct Hose Installation

  1. Remove the hose from the package, and attach it to the duct flange on the cover of the machine.
  2.  Turn the tube, aim exhaust fume collecting hood with the smoke outlet. Adjust the suction distance based on the application.
  • When adjusting the direction of suction duct hose, try to maintain a broad loop or bend radius of the hose, otherwise it will affect the suction force. The suction inlet shall directly face     the working point. Keep the distance within 150mm.

  • Try to avoid areas with excessive air flow, otherwise suction force will be affected or diminish completely.

8.3  Machine Operating Instructions 

Plug in and check if the power plug is properly fit into the socket. 

Turn on the power switch (Picture 1). 

 

Adjust the speed-adjusting knob to start the machine according to different needs on the air flow (Picture 2).

  • Before starting the machine, the speed-adjusting knob should 

    be adjusted to the OFF position. 

The air flow should be set according to the actual demand. It should not be set too high or too low. 

 

Excessive air flow increases the power consumption as well as the noise level. 

8.4  Operator Interface Button Functions 

 

Power Switch button

Pressing the power switch on the remote control or the machine control panel should cause the machine to start running and the orange light on the machine control panel should turn ON. Pressing the power button on the remote or the machine control panel again should cause the machine to stop running and the orange indicator light on the machine control panel should turn OFF.

  • In the event that the machine takes a long time to shutdown, please turn OFF the machine main power switch and unplug the power plug.

▶Air Volume Up Button

Press this button when the machine is running, the number on digital tube display increases in multiples of 10, the maximum number is 100 which means the machine is running in full speed.

 

▶Air Volume Down Button

Press this button when the machine is running, the number on digital display decreases in multiples of 10.

 

▶Confirm/Set Button

If the machine is in alarm status and buzzer sounds, press the Confirm/Set button to turn OFF the alarm. If the machine is not in alarm status, press the Confirm/Set button to check the total working hours of the machine.

 

▶Panel  Lock-up

Press this button on the remote when the machine is working, all function keys on the machine control panel will be locked. Press again or reboot the machine to unlock.

  • Before starting the machine, the speed-adjusting knob should be adjusted to the OFF position. 

This product uses disposable filtering elements. When these elements have been use to a certain extent, they need to be cleaned or replaced in order to guarantee the good purifying effect of the machine. 

1. Pre-filter

Use method: Place the Pre-filter on top of Middle Filter. The front side (rough side) is facing upwards (air inlet direction). When the accumulated dust on the Pre-filter is over 70% and cannot be cleaned any more, please replace the Pre-filter with a new one. 

2. Middle Filter 

Use method: With the handle side facing up, put the Middle Filter  inside the Main Filter. It shall be immediately cleaned off when the accumulated dust on the Middle Filter evidently affects the suction power. When it cannot be cleaned any more, please replace the Middle Filter with a new one.

3. Main Filter

Use method: With the handle side facing up, place the Main Filter at the bottom inside the machine. When it cannot effectively eliminate the peculiar smell in the smoke, please replace it with a new one. 

  • The power source for this machine must fall within the specified nominal voltage scope (subject to the power identification on  the machine body). 
  • It is strictly forbidden to use this machine with excessive high or low voltage, if the ambient voltage is unstable, please turn off the machine, unplug the power plug and use it again once  the power has stabilized.
  • While using the machine, the ambient temperature range of the gas and the dust which is sucked into the air inlet should be within the range of atmospheric temperature to a maximum of  60 ºC. 
  • Never use the machine when the temperature is higher or lower than this temperature range.
  • When using the machine, the humidity of the gas and the dust sucked into the air inlet should be between the range of 40%-80%. If the humidity is excessively high, the filter element will become ineffective rapidly and the internal circuit will be damaged. Never use the machine when the humidity is higher than 80%.
  • If the machine has a primary cotton filter, then this filter must be properly installed before machine use. The primary cotton filter is considered a disposable consumable item and should be  replaced once it becomes clogged. (DO NOT WASH AND REUSE). Please replace the primary cotton filter with an OEM  part regularly. Never use the machine without the primary    cotton   filter or with a poorly performing primary cotton filter.
  • It is strictly forbidden to use this machine without a filter element because the fumes or the dust particles sucked in the machine   directly will cause damage to the air blower and the control system. Any fault caused by machine use under the previously stated conditions shall be serviced at the user's own cost.
  • Do not continue to use the machine when the filter element or the cotton filter is clogged. This will greatly shorten the service life of the machine and will damage the machine. Please clean and maintain the machine regularly and replace the filter element regularly to ensure the proper operation of the machine.
  • In the event that your machine filter element becomes clogged, the suction force is lowered or the filter element for foreign odor removal fails to remove the odor, it is not permitted to use this machine by reducing the machine's number of layers of the filter elements or without utilizing the primary filter element or cotton filter. Please replace the filter element and primary cotton filter with OEM filters.
  • Never open the machine for maintenance by yourself,  the   warranty sticker on the machine is the only voucher you have to  enjoy after-sales service so please don't tear it up or damage it.

 

The warranty will not cover any losses or damage that may be incurred by the user if the previously stated instructions are not followed.